Error Codes
If a Baxi boiler develops a problem, the boiler will display an error code to help you identify the issue. The most common of these error codes are explained below.
- Baxi 200 Combi 2
- Baxi 400 Combi 2
- Baxi 600 Combi 2
- Baxi 800 Combi 2
- Baxi Assure 500 Combi 2
- Baxi 600 System 2
- Baxi 800 System 2
- Baxi Assure 500 System 2
Error code | Possible fault |
---|---|
A.00.28 | Solar temperature sensor is either removed or measures a temperature below range. |
A.00.29 | Solar temperature sensor is either shorted or measures a temperature above range. |
A.00.34 | Outdoor temperature sensor expected but not detected. |
A.02.06 | Low system pressure in heating circuit. |
A.02.18 | OBD error. |
A.02.36 | Functional device disconnected. |
A.02.37 | Passive functional device disconnected. |
A.02.45 | Connection error. |
A.02.46 | Device priority error. |
A.02.48 | Unit function configuration error. |
A.02.49 | Failed node initialisation. |
A.02.54 | OpenTherm bus power supply error. |
A.02.55 | Incorrect or missing serial number. |
A.02.76 | Internal memory reserved for full customisation of settings. No further changes can be made. |
E.00.04 | Return temperature sensor disconnected. |
E.00.05 | Return temperature sensor short circuited. |
E.00.16 | DHW tank temperature sensor not connected. |
E.00.17 | DHW tank temperature sensor short-circuited. |
E.00.20 | The flue gas temperature sensor is not connected or measured a temperature below the range. |
E.00.21 | The flue gas temperature sensor has short-circuited or measured a temperature above the range. |
E.01.04 | Flame loss detected five times in 24 hours. |
E.01.12 | Temperature measured by return sensor greater than flow temperature. |
E.01.17 | No water circulation (permanent). |
E.01.20 | Maximum flue gas temperature reached. |
E.02.13 | Total stoppage of the boiler (antifreeze function not active). |
E.02.17 | Permanent communication failure between gas valve and boiler PCB. |
E.02.35 | Critical safety device disconnected. |
E.02.39 | Minimum pressure not reached after 6 minutes of automatic filling. |
E.02.47 | Connection to external device unsuccessful. |
E.04.01 | Flow temperature sensor short circuited. |
E.04.02 | Flow temperature sensor disconnected. |
E.04.03 | Maximum flow temperature exceeded or flow temperature sensor short circuited. |
E.04.08 | Maximum safe temperature value reached. |
E.04.10 | Burner failed to ignite after 4 attempts. |
E.04.12 | Ignition failure -flame monitoring. |
E.04.13 | Fan impeller blocked or maximum rpm exceeded. |
E.04.17 | Fault in gas valve control circuit. |
E.04.18 | The flow temperature is below the minimum temperature or the flow temperature sensor is not connected. |
E.04.23 | Communication internal stoppage. |
E.04.254 | Fault in gas valve control circuit. |
E.04.29 | Communication internal stoppage. |
E.04.54 | Fault in gas valve control circuit. |
H.00.42 | Pressure sensor open/faulty. |
H.00.81 | Room unit disconnected. |
H.01.00 | Temporary communication failure between gas valve and boiler PCB. |
H.01.05 | Maximum temperature difference value between flow and return reached. |
H.01.08 | Flow temperature increase in heating mode too quick. Temporary stoppage of 10 minutes. |
H.01.14 | Maximum flow or return temperature value reached. |
H.01.18 | No water circulation (temporary). |
H.01.21 | Flow temperature increase during domestic hot water operation too fast. |
H.02.00 | Reset in progress. |
H.02.02 | Waiting for configuration settings to be entered (CN1,CN2). |
H.02.03 | Configuration settings (CN1,CN2) not entered correctly. |
H.02.04 | PCB settings cannot be read. |
H.02.05 | Setting memory not compatible with the boiler PCB type. |
H.02.07 | Low pressure in heating circuit (permanently). |
H.02.09 | Partial stoppage of the boiler (antifreeze function active). |
H.02.10 | Total stoppage of the boiler (antifreeze function not active). |
H.02.70 | External unit heat recovery test failed. |
H.03.00 | No identification data for boiler safety device. |
H.03.02 | Temporary flame loss. |
H.03.05 | Power supply voltage too low. |
H.03.54 | Temporary flame loss. Shutdown due to the power supply voltage being too low. |
I can't find my error code | Call Technical Support |
- Baxi Platinum Compact Combi
- Baxi Duo-tec Compact Combi
- Baxi Megaflo Compact System
- Main Eco Compact Combi & System
- Baxi 600 Combi & System
- Baxi 800 Combi & System
- Baxi Duo-tec Combi
- Baxi Assure Combi & System
- Baxi Platinum Combi
- Potterton Assure Combi & System
- Baxi Platinum + Combi
- Baxi Megaflo System
- Baxi EcoBlue Combi & System
Error code | Possible fault |
---|---|
E09 | Gas valve connection fault. |
E10 | External probe fault. |
E12 | Differential water flow switch fault (still open). |
E13 | Differential water flow switch fault (still closed). |
E15 | Gas valve command fault. |
E20 | Central heating NTC sensor fault - short circuit/open circuit. |
E28 | Flue NTC sensor fault- short circuit/open circuit. |
E40 | Return central heating NTC sensor fault- short circuit/open circuit. |
E50 | DHW NTC sensor fault (tank boiler) - short circuit/open circuit. |
E83 / E84 / E85 / E86 / E87 | No communication. |
E103 | Safety Assist battery is exhausted. |
E104 | Faulty Safety Assist PCB. |
E107 | PCBs not synchronised. |
E109 | Precirculation alarm. |
E110 | (i) Boiler max. temperature exceeded for gradient (probable pump jammed or air in the circuit). (ii) Safety thermostat sensor tripped. |
E118 | Water pressure LOW (<0.5 bar). |
E125 | Water circulation fault. |
E128 | Safety error for frequent loss of flame. |
E129 | Safety error for frequent loss of flame with max correction during ignition during Calibration Function. |
E130 | Flue thermostat sensor tripped (lockout). |
E133 | Gas supply fault. Check the power supply, sensing electrode, spark electrode and cable. |
E134 | Elapsed time gas valve open without gas (short request in a short period). |
E135 | Internal error. |
E154 | Plausibility test (flow/return). |
E160 | Fan fault. |
E270 | Dry fire. |
E317 / 162 | Wrong power supply electrical frequency (Hz). |
E321 / 163 | Domestic Hot Water NTC sensor fault (s.c.). |
E321 / 163 | Domestic Hot Water NTC sensor fault (o.c.). |
E384 / 164 | False flame (parasitic flame). |
E385 / 165 | Under voltage. |
E430 / 166 | Water pressure temporary fault. |
E430 / 166 + Flame 'crossed' | Water pressure test failed. |
I can't find my error code | Call Technical Support |