The Remeha Gas 220 Ace is a premium floor-standing boiler that exceeds expectations in performance capability and design simplicity.


It’s a free-standing, gas fired, high-efficiency condensing boiler range that sets standards and puts you in control. And thanks to an innovative design, based on an aluminium monobloc platform, this boiler is effortlessly lightweight, manoeuvrable and adaptable to space-saving configurations.

Features and Benefits

Wide range of outputs

Available in 160, 200, 250 and 300kW models 

    Modular design for any space

    All connections and pipework enter the top so Gas 220 Ace models can be positioned side to side or back to back

      A more stable and reliable design

      The monobloc heat exchanger is built from a single piece of aluminium which makes it inherently more stable and reliable 

        Lightweight and manoeuvrable

        Supplied with integral wheels so it can be delivered through a standard door and lifts, plus easy to manoeuvre within plant rooms

          Total control as standard

          A specially designed microprocessor is at the heart of the control system with time and temperature controls supplied as standard, set and controlled by the end user

            High efficiency

            High efficiency up to 97.7% 
              Show More
              Show Less

              Product Literature

              Installation & Service Manuals

              Installation & Service Manuals

              Product Documentation

              No documentation available.

              Specification Guides

              Specification Guides

              Product Documentation

              No documentation available.

              Technical Specifications

              Technical Specifications

              Product Documentation

              No documentation available.

              BIM Files

              BIM Files

              Product Documentation

              No documentation available.

              CAD Files

              CAD Files

              Product Documentation

              No documentation available.

              Remeha-Gas-220-Ace-Dimensions

              Dimensions

              160kW - 300kW

              Boiler Width = 800mm
              Boiler Height = 1662mm
              Boiler Depth = 657mm

              Technical Specification 

              Remeha Gas 220 Ace160200250300
              Performance
              Nominal heat output central heating operation @ 80/60°C kW (min-max)31.5-152.139.4-194.449.4-243.359.0-290.9
              Nominal heat output central heating operation @ 50/30°C kW (min-max)34.7-161.143.2-209.854.1-261.065.0-310.7
              Nominal input (Hi) (min-max)32-15640-20050-25060-299
              Efficiency
              Part L 2 seasonal efficiency GCV95.9%95.5%95.6%95.8%
              Full load central heating efficiency (Hi) (80/60°C) (92/42/EEC)97.5%97.2%97.3%97.3%
              Part load central heating efficiency (92/42/EEC) (return temperature 30°C)108.5%108%108.2%108.4%
              Useful efficiency at rated heat output and high temperature regime (ErP) ŋ487.8%87.6%87.7%87.7%
              Useful heat output at 30% of rated heat output and low temperature regime (ErP) ŋ197.8%97.3%97.5%97.7%
              Gas
              Standard fuelNatural gasNatural gasNatural gasNatural gas
              Optional fuel adjustment – see installation & service manualLPG (propane)LPG (propane)LPG (propane)LPG (propane)
              Gas consumption G20 (H gas) min-max (m3/h)3.4-16.54.2-21.25.3-26.56.4-31.6
              Gas consumption G31 (propane) min-max (m3/h)1.4-6.31.6-8.22.1-10.22.8-12.2
              Gas inlet pressure G20 (H gas) min-max (Mbar)17-2517-2517-2517-25
              Gas inlet pressure G31 (propane) min-max (Mbar)37-5037-5037-5037-50
              Gas connection size BSP inches1” male thread1 ½” male thread1 ½” male thread1 ½” male thread
              Flame protectionIonisationIonisationIonisationIonisation
              IgnitionElectronicElectronicElectronicElectronic
              Flue (supplied as standard for conventional flue, option for room-sealed available)
              Flue diameter mm I/D150200200200
              Air inlet diameter mm I/D150200200200
              Flue gas quantity (1) min-max (kg/h)57-27771-35589-444107-531
              Maximum counter pressure (Pa)200150150150
              Hydraulics
              Water content litres17333333
              Hydraulic resistance (ΔT=20k) mbar190100150200
              Hydraulic resistance (ΔT=20k) I/s1.812.312.903.46
              Condensate connection (OD mm)40404040
              Connection size BSP inches flow/return (“) (mm)1 ¼” (40mm)2 (50mm)2 (50mm)2 (50mm)
              Standard operating temperature °C20-9020-9020-9020-90
              Max operating temperature °C90909090
              Max water temperature °C110110110110
              Max water operating pressure (bar)5666
              Min water operating pressure (bar)0.80.80.80.8
              General
              Boiler weight (kg)205245245245
              Dimension (WxHxD)800 x 1662 x 657800 x 1662 x 657800 x 1662 x 657800 x 1662 x 657
              BREEAM NOx (Mg/kWh)22403835
              Electrical
              Nominal power(VAC/Hz)230/50230/50230/50230/50
              Power consumption min-max (w)47-27557-20457-32348-343
              Modulating input (V.dc)0-100-100-100-10
              Fuse rating amps6.36.36.36.3
              Electrical protection index (ip)IPX1BIPX1BIPX1BIPX1B